Air-tight radon chamber for determination of supported radon concentration in water / Ahmad Saat, Nor Shalina Zainal and Zaini Hamzah

Humans are exposed to radiation from natural radionuclides of uranium, thorium and Potassium-40. Isotopes of uranium and thorium decay in chains form through various daughter radionuclides before reaching stability. Radon is a radioactive gas produced in the decay chains, an offshoot of soluble raio...

Full description

Saved in:
Bibliographic Details
Main Authors: Saat, Ahmad, Zainal, Nor Shalina, Hamzah, Zaini
Format: Book Section
Language:English
Published: Research Innovation Business Unit 2014
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/73399/1/73399.pdf
https://ir.uitm.edu.my/id/eprint/73399/
http://www.iidex.com.my
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uitm.ir.73399
record_format eprints
institution Universiti Teknologi Mara
building Tun Abdul Razak Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Mara
content_source UiTM Institutional Repository
url_provider http://ir.uitm.edu.my/
language English
topic Chemical engineering
Special processes and operations
Water gas
spellingShingle Chemical engineering
Special processes and operations
Water gas
Saat, Ahmad
Zainal, Nor Shalina
Hamzah, Zaini
Air-tight radon chamber for determination of supported radon concentration in water / Ahmad Saat, Nor Shalina Zainal and Zaini Hamzah
description Humans are exposed to radiation from natural radionuclides of uranium, thorium and Potassium-40. Isotopes of uranium and thorium decay in chains form through various daughter radionuclides before reaching stability. Radon is a radioactive gas produced in the decay chains, an offshoot of soluble raionuclide, radium. There are three main isotopes of radon, Radon-222, Radon-220 and Radon-219. Of the three isotopes, Radon-222 is more radiological importance. When present in water radon would gain entry into our body though ingestion. Being a relatively high energy alpha particle emitter together with its progenies, they could initiate radiological risk to our body, especially when ingested at high concentration. The common method of determining radon concentration in water is by measuring the gamma-rays emitted by the progenies of radon. In the present study an air-tight chamber was developed using discarded metal container and coupled to a continuous air radon monitor and solid-state nuclear track detector for determination of supported radon concentration in water samples. Metal container was preferred against plastic or polyvinyl chloride (PVC) container to avoid static electricity attraction of the emitted alpha particles on to the container’s wall. This might render underestimation of results. Prior to measurement the chamber was optimized for sample temperature, chamber gas content, measurement period and pumping rate. The solid-state track detector was calibrated against the continuous air radon monitor and tested. The optimized conditions were room temperature, purged using nitrogen gas for about five minutes, measurement period of twenty-four hours, and pumping rate of 1.2 litres per minute. Results were verified using gamma-ray spectrometry. Repeatability, accuracy and precision study was also carried out. The continuous air radon monitor gives hourly diurnal radon concentration in the chamber. A plot and mathematical fittings of the hourly concentration would give the supported radon concentration in water samples. The exposed solid-state nuclear track detector was etched using 6N sodium hydroxide solution at seventy degree Celsius for six hours, and cleaned using running water for one hour and left to dry. The etched tracks were observed and counted under four hundred times magnification digital optical microscope. Using calibration factor the radon concentration in the water samples can be calculated. The verification using gamma-ray spectrometry was carried out by the determination of gamma-rays emitted by daughters of radon, assuming they are in secular equilibrium condition. Very good agreement of results with standard gamma-ray spectrometry method was obtained. For precision, accuracy and repeatability studies, standard liquid sample of known radium concentration were prepared and measured using the developed chamber method. Precision, accuracy and repeatability of within less than ten percent variation were obtained. The developed method was able to determine radon concentration in water with good accuracy, relatively fast and cheap. The chamber developed was then applied to water samples collected from the water supply chains in Cameron Highlands, Pahang area. Samples were collected at water sources (rivers and dams), various parts of treatment plants and homes for drinking and other domestic usage. Results indicated that supported radon concentration in the water samples were all below the permissible limit, while the ingestion dosages implicated minimum radiological risks to consumers.
format Book Section
author Saat, Ahmad
Zainal, Nor Shalina
Hamzah, Zaini
author_facet Saat, Ahmad
Zainal, Nor Shalina
Hamzah, Zaini
author_sort Saat, Ahmad
title Air-tight radon chamber for determination of supported radon concentration in water / Ahmad Saat, Nor Shalina Zainal and Zaini Hamzah
title_short Air-tight radon chamber for determination of supported radon concentration in water / Ahmad Saat, Nor Shalina Zainal and Zaini Hamzah
title_full Air-tight radon chamber for determination of supported radon concentration in water / Ahmad Saat, Nor Shalina Zainal and Zaini Hamzah
title_fullStr Air-tight radon chamber for determination of supported radon concentration in water / Ahmad Saat, Nor Shalina Zainal and Zaini Hamzah
title_full_unstemmed Air-tight radon chamber for determination of supported radon concentration in water / Ahmad Saat, Nor Shalina Zainal and Zaini Hamzah
title_sort air-tight radon chamber for determination of supported radon concentration in water / ahmad saat, nor shalina zainal and zaini hamzah
publisher Research Innovation Business Unit
publishDate 2014
url https://ir.uitm.edu.my/id/eprint/73399/1/73399.pdf
https://ir.uitm.edu.my/id/eprint/73399/
http://www.iidex.com.my
_version_ 1762396033263861760
spelling my.uitm.ir.733992023-03-30T07:04:29Z https://ir.uitm.edu.my/id/eprint/73399/ Air-tight radon chamber for determination of supported radon concentration in water / Ahmad Saat, Nor Shalina Zainal and Zaini Hamzah Saat, Ahmad Zainal, Nor Shalina Hamzah, Zaini Chemical engineering Special processes and operations Water gas Humans are exposed to radiation from natural radionuclides of uranium, thorium and Potassium-40. Isotopes of uranium and thorium decay in chains form through various daughter radionuclides before reaching stability. Radon is a radioactive gas produced in the decay chains, an offshoot of soluble raionuclide, radium. There are three main isotopes of radon, Radon-222, Radon-220 and Radon-219. Of the three isotopes, Radon-222 is more radiological importance. When present in water radon would gain entry into our body though ingestion. Being a relatively high energy alpha particle emitter together with its progenies, they could initiate radiological risk to our body, especially when ingested at high concentration. The common method of determining radon concentration in water is by measuring the gamma-rays emitted by the progenies of radon. In the present study an air-tight chamber was developed using discarded metal container and coupled to a continuous air radon monitor and solid-state nuclear track detector for determination of supported radon concentration in water samples. Metal container was preferred against plastic or polyvinyl chloride (PVC) container to avoid static electricity attraction of the emitted alpha particles on to the container’s wall. This might render underestimation of results. Prior to measurement the chamber was optimized for sample temperature, chamber gas content, measurement period and pumping rate. The solid-state track detector was calibrated against the continuous air radon monitor and tested. The optimized conditions were room temperature, purged using nitrogen gas for about five minutes, measurement period of twenty-four hours, and pumping rate of 1.2 litres per minute. Results were verified using gamma-ray spectrometry. Repeatability, accuracy and precision study was also carried out. The continuous air radon monitor gives hourly diurnal radon concentration in the chamber. A plot and mathematical fittings of the hourly concentration would give the supported radon concentration in water samples. The exposed solid-state nuclear track detector was etched using 6N sodium hydroxide solution at seventy degree Celsius for six hours, and cleaned using running water for one hour and left to dry. The etched tracks were observed and counted under four hundred times magnification digital optical microscope. Using calibration factor the radon concentration in the water samples can be calculated. The verification using gamma-ray spectrometry was carried out by the determination of gamma-rays emitted by daughters of radon, assuming they are in secular equilibrium condition. Very good agreement of results with standard gamma-ray spectrometry method was obtained. For precision, accuracy and repeatability studies, standard liquid sample of known radium concentration were prepared and measured using the developed chamber method. Precision, accuracy and repeatability of within less than ten percent variation were obtained. The developed method was able to determine radon concentration in water with good accuracy, relatively fast and cheap. The chamber developed was then applied to water samples collected from the water supply chains in Cameron Highlands, Pahang area. Samples were collected at water sources (rivers and dams), various parts of treatment plants and homes for drinking and other domestic usage. Results indicated that supported radon concentration in the water samples were all below the permissible limit, while the ingestion dosages implicated minimum radiological risks to consumers. Research Innovation Business Unit 2014 Book Section NonPeerReviewed text en https://ir.uitm.edu.my/id/eprint/73399/1/73399.pdf Air-tight radon chamber for determination of supported radon concentration in water / Ahmad Saat, Nor Shalina Zainal and Zaini Hamzah. (2014) In: IIDEX 2014: invention, innovation & design exposition. Research Innovation Business Unit, Shah Alam, Selangor, p. 129. (Submitted) http://www.iidex.com.my
score 13.252575