Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath

Diabetes is a chronic disease that occurs due to deficiency or improper use of insulin by body tissues. It is currently diagnosed invasively by measuring blood glucose. This paper reports modelling and simulation of a PolyMUMPS device proposed for a non-invasive screening of diabetes. The device is...

全面介紹

Saved in:
書目詳細資料
Main Authors: Rabih, A.A.S., Dennis, J.O., Khir, M.H.M., Ahmed, M.G., Mian, M.U.
格式: Conference or Workshop Item
出版: American Institute of Physics Inc. 2016
在線閱讀:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85005973713&doi=10.1063%2f1.4968101&partnerID=40&md5=41d83faf63b15064072a039eea2a5b0c
http://eprints.utp.edu.my/30648/
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id my.utp.eprints.30648
record_format eprints
spelling my.utp.eprints.306482022-03-25T07:13:34Z Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath Rabih, A.A.S. Dennis, J.O. Khir, M.H.M. Ahmed, M.G. Mian, M.U. Diabetes is a chronic disease that occurs due to deficiency or improper use of insulin by body tissues. It is currently diagnosed invasively by measuring blood glucose. This paper reports modelling and simulation of a PolyMUMPS device proposed for a non-invasive screening of diabetes. The device is electromagnetically driven at its resonance frequency using Lorenz force, while the output is detected by capacitive means. The resonance frequency of the first mode was obtained by CoventorWare software and it was found to be 18.552 kHz compared to its modelled value of 17.211 kHz, within an error of 7.2 . Maximum displacement of 8.35 μm and capacitance of 29.57 fF were obtained when the device was driven by applying 15 mA current and 50 mT magnetic field. © 2016 Author(s). American Institute of Physics Inc. 2016 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85005973713&doi=10.1063%2f1.4968101&partnerID=40&md5=41d83faf63b15064072a039eea2a5b0c Rabih, A.A.S. and Dennis, J.O. and Khir, M.H.M. and Ahmed, M.G. and Mian, M.U. (2016) Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath. In: UNSPECIFIED. http://eprints.utp.edu.my/30648/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description Diabetes is a chronic disease that occurs due to deficiency or improper use of insulin by body tissues. It is currently diagnosed invasively by measuring blood glucose. This paper reports modelling and simulation of a PolyMUMPS device proposed for a non-invasive screening of diabetes. The device is electromagnetically driven at its resonance frequency using Lorenz force, while the output is detected by capacitive means. The resonance frequency of the first mode was obtained by CoventorWare software and it was found to be 18.552 kHz compared to its modelled value of 17.211 kHz, within an error of 7.2 . Maximum displacement of 8.35 μm and capacitance of 29.57 fF were obtained when the device was driven by applying 15 mA current and 50 mT magnetic field. © 2016 Author(s).
format Conference or Workshop Item
author Rabih, A.A.S.
Dennis, J.O.
Khir, M.H.M.
Ahmed, M.G.
Mian, M.U.
spellingShingle Rabih, A.A.S.
Dennis, J.O.
Khir, M.H.M.
Ahmed, M.G.
Mian, M.U.
Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath
author_facet Rabih, A.A.S.
Dennis, J.O.
Khir, M.H.M.
Ahmed, M.G.
Mian, M.U.
author_sort Rabih, A.A.S.
title Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath
title_short Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath
title_full Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath
title_fullStr Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath
title_full_unstemmed Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath
title_sort design of polymumps device for diabetes screening via acetone vapor detection in exhaled breath
publisher American Institute of Physics Inc.
publishDate 2016
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85005973713&doi=10.1063%2f1.4968101&partnerID=40&md5=41d83faf63b15064072a039eea2a5b0c
http://eprints.utp.edu.my/30648/
_version_ 1738657137103470592
score 13.252575