Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath
Diabetes is a chronic disease that occurs due to deficiency or improper use of insulin by body tissues. It is currently diagnosed invasively by measuring blood glucose. This paper reports modelling and simulation of a PolyMUMPS device proposed for a non-invasive screening of diabetes. The device is...
Saved in:
Main Authors: | , , , , |
---|---|
格式: | Conference or Workshop Item |
出版: |
American Institute of Physics Inc.
2016
|
在線閱讀: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85005973713&doi=10.1063%2f1.4968101&partnerID=40&md5=41d83faf63b15064072a039eea2a5b0c http://eprints.utp.edu.my/30648/ |
標簽: |
添加標簽
沒有標簽, 成為第一個標記此記錄!
|
id |
my.utp.eprints.30648 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.306482022-03-25T07:13:34Z Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath Rabih, A.A.S. Dennis, J.O. Khir, M.H.M. Ahmed, M.G. Mian, M.U. Diabetes is a chronic disease that occurs due to deficiency or improper use of insulin by body tissues. It is currently diagnosed invasively by measuring blood glucose. This paper reports modelling and simulation of a PolyMUMPS device proposed for a non-invasive screening of diabetes. The device is electromagnetically driven at its resonance frequency using Lorenz force, while the output is detected by capacitive means. The resonance frequency of the first mode was obtained by CoventorWare software and it was found to be 18.552 kHz compared to its modelled value of 17.211 kHz, within an error of 7.2 . Maximum displacement of 8.35 μm and capacitance of 29.57 fF were obtained when the device was driven by applying 15 mA current and 50 mT magnetic field. © 2016 Author(s). American Institute of Physics Inc. 2016 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85005973713&doi=10.1063%2f1.4968101&partnerID=40&md5=41d83faf63b15064072a039eea2a5b0c Rabih, A.A.S. and Dennis, J.O. and Khir, M.H.M. and Ahmed, M.G. and Mian, M.U. (2016) Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath. In: UNSPECIFIED. http://eprints.utp.edu.my/30648/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
Diabetes is a chronic disease that occurs due to deficiency or improper use of insulin by body tissues. It is currently diagnosed invasively by measuring blood glucose. This paper reports modelling and simulation of a PolyMUMPS device proposed for a non-invasive screening of diabetes. The device is electromagnetically driven at its resonance frequency using Lorenz force, while the output is detected by capacitive means. The resonance frequency of the first mode was obtained by CoventorWare software and it was found to be 18.552 kHz compared to its modelled value of 17.211 kHz, within an error of 7.2 . Maximum displacement of 8.35 μm and capacitance of 29.57 fF were obtained when the device was driven by applying 15 mA current and 50 mT magnetic field. © 2016 Author(s). |
format |
Conference or Workshop Item |
author |
Rabih, A.A.S. Dennis, J.O. Khir, M.H.M. Ahmed, M.G. Mian, M.U. |
spellingShingle |
Rabih, A.A.S. Dennis, J.O. Khir, M.H.M. Ahmed, M.G. Mian, M.U. Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath |
author_facet |
Rabih, A.A.S. Dennis, J.O. Khir, M.H.M. Ahmed, M.G. Mian, M.U. |
author_sort |
Rabih, A.A.S. |
title |
Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath |
title_short |
Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath |
title_full |
Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath |
title_fullStr |
Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath |
title_full_unstemmed |
Design of PolyMUMPS device for diabetes screening via acetone vapor detection in exhaled breath |
title_sort |
design of polymumps device for diabetes screening via acetone vapor detection in exhaled breath |
publisher |
American Institute of Physics Inc. |
publishDate |
2016 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85005973713&doi=10.1063%2f1.4968101&partnerID=40&md5=41d83faf63b15064072a039eea2a5b0c http://eprints.utp.edu.my/30648/ |
_version_ |
1738657137103470592 |
score |
13.252575 |